fan bearing

A Fan That Cannot Be Balanced

A power plant kept getting above normal levels of unbalance on a 5000 horsepower 720 RPM fan. They had made several attempts trying to balance the fan, all of which failed. It was then that they made the decision to call in Nelson Baxter who is the manager of Horner’s EMDS Division. Equipment: A 5000 HP 720 RPM fan at a Power Plant. Symptoms: Above normal levels of unbalance that resisted balance efforts. Several attempts were made to balance the fan, all of which were unsuccessful. Test Results: After attempting several balance shots in an I.D. fan, the casing vibration levels [...]

A Fan That Cannot Be Balanced2021-01-08T23:18:48-05:00

Cement Fan Repair

The Springfield Division received a call from a Cement Company just before the Memorial Day weekend, for help with a large 8’ diameter propeller style fan that self-destructed. The fan lost one blade and bent over 6” of the rest of the blade tips. Mark Russell and Kim Shellabarger had a meeting with the plant manager on Friday and learned that the request was for a “patch job” with no warranty, just to get them up and running until they could acquire and install a new fan. We were also informed of the high production loss per day, while this fan [...]

Cement Fan Repair2020-03-06T15:50:04-05:00
Go to Top