blower vibration

Advanced Diagnostic Services and Preventative Maintenance

A major steel mill was looking to upgrade their maintenance practices thru predictive maintenance vibration analysis. There were several meetings with Brad Barton of Horner’s Electrical Mechanical Diagnostics Service (EMDS) group to identify equipment and understand their expectations. The EMDS reporting was covered in depth, a vibration collection route was laid out and frequency of reporting established. The machines identified ranged from 10,000 hp AC motors to smaller AC and DC motors in the range of 100hp up to 1250 hp as well as gearboxes. Horner’s field service group installed remote accelerometers on equipment deemed not safe for personnel to enter [...]

Advanced Diagnostic Services and Preventative Maintenance2022-01-26T23:19:34-05:00

High Speed Motion Camera

Motion Magnification See what’s really happening to your equipment in real time.  Pinpoint the root cause of the vibration or dynamic problems costing you time and money! Key Benefits Faster, easier, and less error-prone diagnosis of vibration and system dynamics enable problems to be pinpointed with more certainty. Enables your reliability and maintenance engineers to pinpoint problem root causes, lower maintenance costs, reduce problem resolution time and machine or plant downtime. Applications Localized Structural Vibration: Bearing pedestals Pipe Rack Duct work Cooling Towers Blowers Frequent Mechanical Failures: Pumps Fans Machine Bases Bent shaft Misalignment  

High Speed Motion Camera2021-01-08T23:41:17-05:00

Vibration Of Microscope In Microsurgery Room

Equipment: A microscope mounted from the ceiling of a surgery room. The special microscope was used by the surgeon during micro-surgery operations which involved replanting severed fingers and toes. Symptoms: The chief surgeon complained that the image was jittery and that it was very tiring to operate under those conditions, particularly when the scope was set for its maximum magnification. Test Data and Observations: The scope was set to its greatest magnification and printed material was placed on the operating table. Vibration was clearly noticeable, just as the surgeon had indicated. Vibration spectra were taken on both the table and the [...]

Vibration Of Microscope In Microsurgery Room2019-09-09T17:18:50-04:00

From Scrap To Like New

A brick manufacturer had a large fan that pulls air, brick and cement dust thru an overhead duct system into a bag house then through the fan and up a stack. The baghouse requires cleaning frequently and during the cleaning cycle the baghouse is bypassed and the material goes through the fan. This causes buildup on the fan blades and thus an imbalance and vibration. The vibration is so severe it cracks the motor base, bearing base and fan housing. The customer has attempted to deal with this by filling the fan base with concrete, welding large angle iron to the [...]

From Scrap To Like New2019-09-03T20:16:15-04:00