POST

Steel Rolling Tandem Mill Motor

A steel manufacturer sent in a steel rolling tandem mill motor after the armature equalizer insulation had failed to ground due to age and time of service. The bearings, bearing journals, and bearing housings were severely damaged. A team of different Horner Divisions came together to complete this project.
Machining Services did an extensive amount of machine work on the shaft and bearing housing. They also turned and undercut the armature when the rewind was completed. Fan and Fabrication manufactured new bearing seal inserts. Horner Coatings sprayed and machined the shaft and bearing housings. They also did the welding of the armature connections. The Indianapolis Repair Shop did the disassembly, armature rewind, reassembly and electrical testing.

Family Owned and Operated

Family owned and operated since 1949, Horner Industrial Group has built its reputation on integrity, standards of excellence and a commitment to customer service.

Other Posts

  • Chiller 1000HP Soft Starter

    An ethanol facility that processes corn into fuel recently upgraded a critical chiller application with the installation of a 1000 HP, 4160V Benshaw medium-voltage soft starter. What began as a transformer repair discussion ultimately evolved into a full system improvement [...]

  • Combine Vibration Troubleshooting

    Horner Field Service was recently asked to troubleshoot a vibration issue with a combine. The call came in to Ralph Coonce on a Thursday afternoon. It didn’t take long for Ralph to determine that he was going to send me. [...]

  • Rubber Plant Motor Failure

    A 400HP WEG motor on the hydraulic power unit of a plant’s main mixer failed due to a catastrophic drive-end (DE) bearing issue. The bearing failure generated sparks and halted the production of raw rubber critical for automotive products. With [...]